AZEV400 - 4 x 50 AMP / 2 x 80 AMP POWER RELAY WITH MONITORING
Features:
- 4 pole 50 A / 480 VAC or 2 pole 80 A / 480 VAC switching capacity
- Contact gap greater than 4.0mm
- Designed for IEC 61851 Mode 3 and SAE J1772 AC Level 2 charging applications
- Meets IEC 62955, IEC 62752, IEC 61008-1, IEC 62052-11 short circuit requirements
- UL, CUR, TUV, and CQC approvals
- Auxiliary NC contact for weld monitoring
- Dielectric strength 5 kVRMS, surge withstand voltage 10 kV
Engineering Resources

Contact ratings | Coil Voltage | Contact forms | Coil Power at pickup voltage | ||
---|---|---|---|---|---|
4x 50 A at 480 VAC, resistive, 85°C, 50k cycles
2x 80 A at 480 VAC, resistive, 85°C, 10k cycles 4x 32 A at 480 VAC, AC1, 50k cycles per IEC 60947-4-1 230A inrush current per IEC 62752 cl. 9.8 |
6,9,12,24 VDC | 4 Form A+1 Form B
2 Form A+1 Form B |
3.6 W | ||
Typical Life - Electrical | Typical Life - Mechanical | Dielectric Strength(at sea level for 1 min.) | |||
4x 50k cycles @50A 480VAC Res
2x 10k cycles @80A 480VAC Res |
200,000 operations | Contact to Coil: 5000 Vrms
Between Open Contacts: 2000 Vrms |
|||
Terminals PC | Terminals Solder / Plug-In | Terminals Bracket Mount | Approvals | Minimum Load | Size in Inches (L x W x H) |